PROPERTY
TO BE TESTED |
TEST METHOD
(IPC-TM-650 unless noted) |
SHELDAHL TYPICAL MEAN VALUE |
| Peel strength, minimum, lb./in. -
width |
- Method 2.4.9
- Method B as received
|
8.0 |
| Tensile strength, minimum,
lb./in.2 |
Method 2.4.19 |
22,000 |
| Elongation, minimum percent |
Method 2.4.19 |
90% |
| Flexural endurance, minimum
cycles |
Method 2.4.3 |
1,000 |
| Dimensional Stability, maximum,
percentage |
- Method 2.2.4
- Method B
- Method C
|
- 0.10
- 0.40
|
| Flammability, minimum percent O2
|
Method 2.3.8 |
30% |
| Dielectric constant, maximum (at
1 MHz) |
Method 2.5.5.3 |
3.5 |
| Chemical Resistance percentage |
Method 2.3.2, Method A |
90% |
| Dissipation factor, maximum (at 1
MHz) |
Method 2.5.5.3 |
0.015 |
| Volume Resistivity, minimum
megohm-cm |
Method 2.5.17 |
107 |
| Surface resistance minimum,
megohms |
Method 2.5.17 |
104 |
| Dielectric strength, minimum
volts/mil |
ASTM-D-149 |
3,000 |
| Moisture and Insulation
Resistance, minimum, megohms |
Method 2.6.3.2 |
104 |
| Moisture Absorption, maximum,
percent |
Method 2.6.2 |
1.0% |